Skip to main content
7 events
when toggle format what by license comment
S Jan 19, 2018 at 3:28 history edited Daniel Griscom CC BY-SA 3.0
Grammar
S Jan 19, 2018 at 3:28 history suggested CommunityBot CC BY-SA 3.0
Check spark arrester in exhaust pipe isn't clogged up with carbon. Undo small bolt adjacent to exhaust pipe and remove insert. All small holes should be clear.
Jan 19, 2018 at 0:54 review Suggested edits
S Jan 19, 2018 at 3:28
Mar 17, 2013 at 13:56 comment added Caleb Turns out that the problem was indeed some sort of pinch or blockage in the fuel line. I removed the float bowl and it was as clean as a whistle. There were only a few drops of gas in the gas filter, though, and playing a bit with the fuel line got the gas flowing much better. After that, the generator started on the first pull. Thanks.
Mar 17, 2013 at 13:53 vote accept Caleb
Mar 6, 2013 at 15:05 comment added HerrBag Starting fluid is pretty volatile, so easy-do-it .. Still not as hot as ether was {KABOOM}.
Mar 6, 2013 at 14:07 history answered Paul CC BY-SA 3.0