Apr 14, 2019 at 23:55 comment added StuballRetired Thank you to all who helped me troubleshoot this problem.
Apr 14, 2019 at 23:54 comment added StuballRetired Found the source of problem. There was a hidden conduit junction box in ceiling under ceiling drywall that contractor 12 years ago covered up. Found loose wire connector and broken wire.
Apr 14, 2019 at 23:50 history edited StuballRetired CC BY-SA 4.0
deleted 11 characters in body
Apr 3, 2019 at 23:17 comment added StuballRetired No backstabbed outlets, all side screws.
Apr 3, 2019 at 22:55 comment added ThreePhaseEel Are the outlets wired with the wires going onto the side-screws, or into the holes in the back?
Apr 3, 2019 at 21:08 comment added StuballRetired Just white and black wires, except for operational overhead stove fan and light that have a ground.
Apr 3, 2019 at 20:00 history edited isherwood CC BY-SA 4.0
deleted 2 characters in body
Apr 3, 2019 at 19:59 answer added manassehkatz-Moving 2 Codidact timeline score: 1
Apr 3, 2019 at 19:59 history edited isherwood CC BY-SA 4.0
added 6 characters in body; edited title
Apr 3, 2019 at 19:58 comment added isherwood What does "no neutral or grounds in line" mean?
Apr 3, 2019 at 19:55 review First posts