3,012 reputation
611
bio website
location United States
age 63
visits member for 3 years, 3 months
seen Jun 11 '12 at 11:28

Retired Electrical Engineer.


Apr
4
revised How can I fix this persistently leaky shower faucet?
added 618 characters in body
Apr
4
comment How can I fix this persistently leaky shower faucet?
@Daniel-Please see my edit.
Apr
4
answered How can I fix this persistently leaky shower faucet?
Apr
3
comment Which should be first, pressure reducer or backflow preventer?
@Scivitri-I believe their sole purpose is to relieve the pressure in a hot water tank, although I do not know if they are also used on tankless for some reason I may not be aware of.
Apr
3
answered How “freely” should a central A/C condenser fan spin
Apr
3
answered Which should be first, pressure reducer or backflow preventer?
Apr
3
revised How should I test my home's humidity?
added 79 characters in body
Apr
3
revised How should I test my home's humidity?
added 902 characters in body
Apr
3
answered How should I test my home's humidity?
Apr
3
comment Convert Light Switch to Light Switch + Outlet Combination
@ pilotcam-Great minds think alike! I guess we called that one @ the same time :)
Apr
3
answered Convert Light Switch to Light Switch + Outlet Combination
Apr
2
comment The main water valve won't open fully after I closed it. How do I shut off the water to replace it?
WARNING! The Electrical breaker panel ground bus is connected to the water main. If the electrical ground wire is connected on the house side of the valve, then when you replace the main shut off valve you will be breaking this return path. This can give you a very nasty (lethal?) shock when you touch the pipes! You can either "jump" the two sections of pipe with a heavy wire (8-6AWG should be do it), or turn off the Breaker panel's Main breaker (leaving you in the dark), or move this ground wire to the street side of the valve (prefered methode - turn off main breaker panel first!).
Apr
2
revised How can I replace my main water shutoff valve?
added 317 characters in body
Apr
2
comment Should a post in a circular concrete form go through the bottom?
@Shirlock- Good call! A lot of people do not do the "mushroom" step. Which helps to keep the post sturdy, plumb and keeps water from wicking up the post.
Apr
2
comment What could cause bubbling toilet when the shower or sink is running?
I agree. Have the waste pipe vent checked out. A bird may have made a nest in your vent pipe on the roof.
Apr
1
comment How can I replace my main water shutoff valve?
@Tester101- Your right! I meant to say ball valve, but in a senior moment it came out gate valve:)
Apr
1
revised How can I replace my main water shutoff valve?
edited body
Apr
1
answered How can I replace my main water shutoff valve?
Mar
31
answered How do I take down my kitchen ceiling to expose my roof above?
Mar
31
answered how to remove this faucet aerator? it just slips