I live in southern California and have worked in the Electrical Wholesale industry for 28 years. I graduated Alabama Technical College with a Degree in Electrical Technology.


Apr
11
comment What fire hazard considerations are there when creating a cable hole between rooms?
Maybe instead of duct seal you might use fire caulk
Apr
11
answered What could be causing this electrical issue?
Apr
10
comment What could be causing this electrical issue?
Depends on which side of the meter it is. Either way they have to unlock the meter for an electrician to do the work on consumer side.
Apr
10
comment Downsides of Linoleum (in kitchen specifically)
My wife uses the smoke detector as a timer. Linoleum melts.
Apr
10
revised Should I apply lacquer over a wall papered with book pages?
added picture to question
Apr
10
comment was it ever legal to use 3 wire cable to operate two circuits one neutral 120 volts?
Yes, there are 2 pole AFCI's. They make them for straight 240V and also make them for shared neutrals. Always match the brand breakers to the panel manufacturer.
Apr
10
comment Why does this toilet clog so often?
@Jon Raynor +1. He nailed my problem from a couple of years ago with this answer. Basically I had the same problem because we didn't use a toilet for days at a time and over the years we had the insufficient flush problem because the jets became clogged with calcium buildup. Changing the toilet fixed it.
Apr
7
revised Is there any danger in pulling a washing machine forward?
Added per @BMitch's response.
Apr
7
revised Is there any danger in pulling a washing machine forward?
Added, some more trouble shooting tips came to me.
Apr
7
answered Is there any danger in pulling a washing machine forward?
Apr
7
comment Is there any danger in pulling a washing machine forward?
2 things to add. When you remove the hot and cold water hoses try to remove them on the washer side. This is where the screen filter are that are on the hose and they should really be cleaned out every time maintenance is done on your machine. The other is never let the drain hose get lower than the pump, or hit the floor. If this happens there is a good chance that the gunky, funky drain water will get on your floor and it is not the easiest thing to clean up.
Apr
6
revised Are tamper resistant outlets required in a cabinet with child proof latches?
Added to match question better
Apr
6
comment Are tamper resistant outlets required in a cabinet with child proof latches?
Child safety latches on cabinet doors are great if you live in earthquake areas too.
Apr
6
answered Are tamper resistant outlets required in a cabinet with child proof latches?
Apr
6
answered How do I determine if the energy savings are worth replacing windows for?
Apr
3
answered Ways to reduce noise in a home near railroad tracks?
Apr
2
answered How can I remove a burn mark on finished wood without replacing the piece entirely?
Apr
2
awarded  Nice Answer
Apr
1
comment Cannot figure out wiring of most basic Honeywell thermostat (heater only)
I know there are some meters that you need at least 60 volts for, like some of the solenoid testers. Some electronic transformers will not show measurement without a load, but I've never heard of A/C use electronic transformers.
Apr
1
comment What could cause a brand new fluorescent fixture to not work?
If you have brown, yellow and blue wires in the junction box and attached them to the same color wires in the fixture, then it sounds like a defective fixture. If the colors are different there is a possibility of wrong wiring. In the US, the better ballast are dual voltage 120/277v but I'm not sure that covers 208/220/240v.